Update Sequence
This section describes the series of steps Visualyse Professional uses to update the simulation at each time step. This well-defined procedure ensures the results generated by Visualyse Professional are always consistent with the input parameters selected.
The process is as follows:
- Update the current time using time step information
- Set the random number seed for this time step
- Update all the define variables
- Update all the positions of the stations
- Update the pointing of each antenna (except if pointing by link)
- Update all links including:
- Calculating the traffic profile for this link for this time step
- Selecting the station, antenna, beam to use for dynamic links
- Updating the pointing of any antenna that uses pointing by link
- Calculating the wanted signal level
- Updating the wanted signal calculation if using power control
- Updating all interference paths
- Updating all link groups
- Update all statistics
- Updating all views and outputting to file any information requested to be logged